Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Practical Nursing ; (36): 1125-1129, 2018.
Article in Chinese | WPRIM | ID: wpr-697156

ABSTRACT

The Micro-infusion syringe pump has been widely used in infusion of various vasoactive agents. There are several modes of syringe replacement with advantages or limitations respectively. It is important to maintain the stability of hemodynamic parameters during the syringe replacement. In the times of the reformation of medical and medical insurance payment, it is worth paying attention to monitor costs of medical consumables. The large sample multicenter study is needed to reveal the relationships between the hemodynamic parameters and the sorts and volume of various vasoactive agents. It will provide the basis for the clinical choice of syringe replacement modes.

2.
Chinese Critical Care Medicine ; (12): 332-337, 2015.
Article in Chinese | WPRIM | ID: wpr-464450

ABSTRACT

ObjectiveTo establish a mathematical formula for choosing the manner of replacement fluid infusion in continuous renal replacement therapy (CRRT), so as to provide the basis for improving the treatment effect. Methods A mathematical formula for choosing the manner of replacement fluid infusion with continuous veno-venous hemofiltration (CVVH) was taken as an example, and it was compared with the result of standard replacement fluid in order to analyze the effect of different manners of infusion.① Comparison parameters: the plasma volume (Vreturn) and some electrolyte concentration (Creturn) in back way of CRRT (if other thing was solute, filter coefficient should be 1.0).② Research objects: the actual replacement fluid (for example, the most complex should be sorted into A and B type) mode (pre or post) was compared with the standard replacement fluid (the A and B in one).③ Based on the formula of standard replacement, four equations in different conditions were derived: pre-dilution and post-dilution mode; same direction and same ratio; same direction and different ratio; different direction and same ratio; different direction and different ratio.Results The calculated results of Vreturn (except hematocrit) and Creturn were same to the standard only following the rule of same direction and ratio for A and B no matter pre-dilution mode or post-dilution mode, and it was different from the standard in others. In pre-dilution mode and post-dilution mode, it showed:① A and B in same direction and different ratio: Vreturn and Creturn were different from the standard for the alterative ratio of B.② A and B in different direction and same ratio: Vreturn was same to the standard, but Creturn was different from the standard for the completely different and more complex computational formula.③ A and B in different direction and different ratio: both Vreturn and Creturn were different from the standard. The different Vreturn was due to the different ratio of B. The different Creturn was caused by different ratio of B and the completely different computational formula.Conclusions① For parts of replacement fluid which must be separated ( for example, bicarbonate formula ), the result is same to the standard, and is predicted and mastered only following the rule of same direction and ratio. Otherwise, we need to calculate the two parameters over and over again. The result will run out of our judgment. The wrongness of losing water and electrolyte disorders maybe come out.② Accordingly,the formula could be used to analyze the same case like the separated replacement infusion, for example, a large number of citrates as regional anticoagulation were infused only in the front of filter, while the replacement fluid can be done in varied forms.

SELECTION OF CITATIONS
SEARCH DETAIL